Anhui Anchuang Electronic Co.,Ltd

安创电子

ANCHUANG ELECTRONIC
  • home
  • Company profile
  • News
  • Products
  • honor
  • guestbook
  • contact
  • 86-0563-6996688
  • 中文版
  • english

Products

  • Tubular Heater Series for Water Heater
  • Tubular Heater Series for Electric Oven/ Microwave Oven
  • Tubular Heater Series for Air Conditioning Equipment
  • Electric Heater Assembly Series for Air Conditioning
  • Tubular Heater Series for Air Conditioning
  • Tubular Heater for Washing Machine
  • Tube heater
  • Aluminum foil heater
  • Toilet heater
  • Electric heating tropical (line)
  • temperature sensor
  • Quartz tube heater Series for microwave oven

contact

Anhui Anchuang Electronic Co.,Ltd

Add.: Standard workshop no.8, science and technology pioneer park, Guangde economic development zone, Anhui,China

Tel: 86-0563-6996688

Fax: 86-0563-6996668

Website: en.ahacdz.com

E-mail: cj@ahacdz.com

home ≡ Products ≡ Tube heater

Tube heater

Time: 2018-02-10 17:02:25 Hits:

Tube heater

Product Presentation:

Application:
It is suitable for the electric heating environment with the rated voltage below 250V, 50 ~ 60Hz, the relative humidity of not more than 90% and the ambient temperature of minus 30 DEG to plus 50 DEG. With a rapid, uniform and safe heating, it is widely used in the thawing of the refrigerator and other electric heating appliances.


Characteristic:
With the aluminum tube as the carrier, the electric heating component with various shapes which is made by placing the silicone rubber heating wire in the aluminum pipe has the maximum temperature of below 150 DEG C and due to that the outer diameter can be divided into two types of φ4.5 and φ6.35, we recommend a design power of less than 35W/m, the products exceeding the above power density should be customized and designed by our company.


Technical indexes

Sequence numberItemUnitIndexComments on a form
1Dimensions and geometrymmMeet customer requirements
2Resistance value deviation%≤±7%
3Normal temperature insulation resistanceMΩ≥100Soaking
4Normal temperature insulation strength
1500V 1min no abnormalitiesSoaking
5Operating temperature (per meter) leakage currentmA≤0.2Soaking
6Terminal connection strengthN≥50N1min no abnormalitiesTerminal on wire
7Intermediate connection strengthN≥36N 1min no abnormalitiesBetween heating wire and wire
8Tube bending diameter retention%≥80
9

Overload test 1.15 times, the rated voltage of the current 96h


No damage after

Experiment, still meet No.2, 3 &4 requirements

At the allowable operating

temperature